Startseite > Products > Software > XORAYA WebGUI
XORAYA WebGUI
The WebGUI is a browser-based user interface for configuring, recording, analyzing and maintaining data loggers.
- Browser-based access to the data logger without installation
- Flexible configuration of all system and interface parameters
- Control and monitoring of data recording
- Accessing and downloading measurement data
- Live statistics and firmware updates via the interface
| Web browser | Chrome, Firefox, Edge or Safari |
|---|---|
| Network | Existing network connection to the device via Ethernet |
Product details
Product description
The WebGUI is a browser-based user interface for configuring, controlling and evaluating XORAYA data loggers. It enables direct access to the device via an IP connection – without the need to install any additional software and regardless of the operating system used. All system and interface parameters can be flexibly configured via the interface, even for complex applications.
Features & functions
The WebGUI offers a comprehensive and flexible option for configuring, controlling and monitoring data loggers directly via the browser. It combines central functions for the entire workflow – from setup to evaluation.
- Browser-based access without installation, platform-independent use
- Complete configuration of all system, interface and logging parameters
- Control of data recording on storage media and stream recording
- Access to measurement data with filter, search and download functions
- Live statistics for monitoring the device, interfaces and data traffic
- Performing firmware updates with a file or via a URL
- Detailed configuration via complete configuration tree (incl. JSON structure)
Compatibility
The WebGUI is generally compatible with XORAYA data loggers with firmware 5. In particular, this includes devices of the newer generation, such as XORAYA N4000 C40, N8000, N16000 and ASU.
Areas of application
The WebGUI is suitable for a wide range of data acquisition and monitoring applications, especially wherever flexible and direct access to the data logger is required. Typical areas of application are vehicle testing, development and testing, bus analysis as well as diagnostic and monitoring tasks in networked systems.
Data recordings can be started, stopped and monitored via the WebGUI, while live statistics and system statuses can be viewed at the same time. This makes it ideal for operational use in the vehicle or test bench when quick access is required without additional software installation.
Project-specific adaptations
The WebGUI already offers extensive options for adapting to different measurement tasks and system requirements. Thanks to the flexible configuration of interfaces, logging parameters and data processing, the data logger can be tailored to specific application scenarios.
In addition , project-specific extensions are also possible – such as individual functions, customized trigger logics or special requirements for data formats and processes. This means that the WebGUI can be optimally integrated into existing processes and tailored precisely to customer-specific requirements.
Technical data
Here you will find a clear and compact summary of all the technical data.
Functions
| Network access | Browser-based access via IP address without installation |
|---|---|
Configuration |
|
Data recording | Start/stop of storage and streaming recordings (PLP data) |
| Measurement data access | Display, filter and download measurement data |
| Statistics | Live monitoring of device, interfaces and data traffic |
| Firmware update |
|
| Support |
|
System requirements
| Browser |
|
|---|---|
| Network |
|
FAQ
In this FAQ you will find answers to frequently asked questions about the XORAYA WebGUI. It provides helpful tips for the efficient use of the software.
When is the XORAYA WebGUI typically used?
The WebGUI is typically used whenever direct access to the data logger is required – without additional software installation and regardless of the end device used.
It is particularly useful in the following situations:
- During ongoing measurements to start/stop recordings and monitor the system status live
- In the vehicle or test bench when quick access via laptop, tablet or remote connection is required
- For commissioning and short-term adjustments, e.g. changes to configurations or interfaces
- For monitoring tasks, such as monitoring bus load, data rates or device status in real time
- In networked environments in which several users need flexible access to the data logger
The big advantage: The WebGUI complements classic PC tools by enabling real-time operational access, especially during recording and during operation.
Which products are compatible with the XORAYA WebGUI?
All products running Firmware 5 are compatible with the WebGUI. In addition, Datacubes can also be configured and controlled via the WebGUI.
Where can I download the XORAYA WebGUI?
The XORAYA WebGUI does not need to be downloaded separately – it is already integrated on the compatible devices. The prerequisite is that firmware version 5 is installed on the device.
In concrete terms, this means
- The WebGUI is part of the device firmware and is provided directly on the device.
- Access is easy via the web browser by entering the IP address (e.g. 192.168.0.1).
- No installation is necessary.