Data logger
XORAYA N2000

XORAYA N2000 |

Its compact design and broad interface coverage make the N2000 particularly flexible to use, especially in test environments with different bus systems.

Product Description

The Xoraya N2000 is a compact data logger that offers good performance and a wide range of interfaces while coming in a rather small package. The device can therefore be used very flexibly. This is particularly advantageous in test environments in which a large number of different bus systems have to be recorded. The logger has interfaces for CAN, RS-232, FlexRay, LIN, analog, 100/1000BASE-T1 and Gbit Ethernet, which can be written at a data rate of up to 2 Gbit/s.

Product Highlights

Technical Data

For a comprehensive list of technical data, please refer to the tab of the same name.
Data RateStorage CapacityTimestampTemperature RangeDimensions
Up to 2 Gbit/sUp to 1 TB100 ns-40 to +65 °C50 x 105 x 215 mm
Data RateUp to 1 Gbit/s
Storage CapacityUp to 1 TB
Timestamp100 ns
Temperatures-40 to +65 °C
Dimensions100 x 50 x 200 mm

Interfaces

Unlike other data loggers in the XORAYA series, the XORAYA N2000 has fixed interface configurations.

Number of configurable slots
Available interfaces HS-CAN, CAN-FD, RS-232, FlexRay, LIN, 100/1000BASE-T1, Gbit Ethernet
ConfigurationHS-CAN / CAN-FDRS-232LINAnalog100/1000BASE-T1Gbit EthernetFlexRay
C6B2GE2A6R4L4644622
C6B4A6L4F264642
ConfigurationInterfaces
C6B2GE2A6R4L46x CAN, 4x RS-232, 4x LIN, 6x analog, 2x 100/1000BASE-T1, 2x Gbit Ethernet
C6B4A6L4F26x CAN, 4x 100/1000BASE-T1, 6x analog, 4x LIN, 2x FlexRay

Errors and omissions excepted.

Product Features

All important technical data of the XORAYA N2000 at a glance:

Hardware

ProcessorXilinx Dual ARM Cortex-A53 (ZU3CG)
Memory128 MB Flash / 2 GB RAM
Data RateUp to 2 Gbit/s
Data StorageUp to 1 TB internal storage
Recording ModesInternal storage / PC via Ethernet
Quick Boot Buffer1.5 GByte / 6 sec
Timestamp100 ns
External Operating Voltage12 V DC (temporarily 6 to 32 V)
Power consumption
(at 12 V)
Standby: max. 1 mA
Operating: max. 3.1 A
Temperature Range-40 to +65 °C
Dimensions50 x 105 x 215 mm (H x W x D)
Weight1.1 kg
Housing Aluminum anodized
OtherActive Cooling, Real-time Clock, Powercap Unit

Software

Operating SystemEmbedded Linux
Storage FormatsX2E Native, X2E ASCII, Carmen-Journal (V3.0), Wireshark PCAP/PCAPNG, Vector BLF, Vector ASCII, XAA for GNLog, DLT AUTOSAR, System Events, NMEA for GPS, Raw RS-232, CSV for Analog/CCP, CSV for Signals, Video Extractor, MATLAB Signals, MDF Signals/Buslogging
Software Protocols CCP/XCP, PLP, XLP
Wake upCAN, RS-232, LIN, FlexRay, Wakeline or Trigger
SoftwareXORAYA Suite, XORAYA WebGUI and XORAYA SDK for Windows & Linux
OtherAutomatic Sleep Mode

Interfaces

Out-of-the-box Configurations
Configuration 1
(C6B2GE2A6R4L4)
6x HS-CAN/CAN-FD
4x RS-232
4x LIN
6x analog
2x 100/1000BASE-T1
2x Gbit Ethernet
Configuration 2
(C6B4A6L4F2)
6x CAN
4x 100/1000BASE-T1
6x Analog
4x LIN
2x FlexRay
Custom Configurations
Number of configurable slots none
Other Interfaces
Non-logging interfaces 1x 12V/Trigger/Wake, 1x USB OTG, 1x LAN Host, 1x Service

Errors and omissions excepted.

Recommended devices

No separate accessories are currently offered for the XORAYA N2000.

Datasheet

User Manual

Access required – Please request via email to wiki@x2e.de

Firmware

Access required – Please request via email to wiki@x2e.de

Customer-specific
customizations

The modular design of the XORAYA N2000 allows numerous customer-specific adaptations. For example, the device can be assembled or retrofitted according to customer requirements. As a result, the data logger can be quickly and efficiently adapted to changing conditions and can continuously grow with your projects.

Interfaces

The number and type of interfaces can be adapted to different customer requirements.

Performance

Adjustments of device performance, e.g. recording rate or storage capacity, are possible.

Software

Additional functions or export formats are available on request.

Installation